Setting parameters for the analytical simplified model

The following parameters are to be specified:

If you want to change the direction of the traveling field, you simply change the sign:

Traveling magnetic fields: analytical simplified model parameters 

Figure 6. Traveling magnetic fields: analytical simplified model parameters

Now you are ready to compute the Lorentz forces:

  1. Enter the relevant parameters in the Process parameters dialog.

  2. Select the region in the furnace.

  3. Check the Lorentz Forces box in the Physical Phenomena dialog.

  4. Start computation by selecting Computation > Start Computation or by clicking on  .