Traveling Fields

In this dialog the parameters for traveling magnetic fields (TMF) can be defined. The details of the implementation and the physical background cab be found in the master thesis of M.Iugam (see Bibliography ).

TMF: continuous model parameters 

Figure 38. TMF: continuous model parameters

TMF: discrete model parameters 

Figure 39. TMF: discrete model parameters

Item

Description

continuous model parameters

Specifies the following parameters:

  • AC Frequency (Hz): The frequency of the traveling wave (default: 50Hz).

  • Traveling wavelength (m): Wavelength of the traveling magnetic wave (default: 0.06m).

  • Magnetic induction (T): Maximum value of magnetic amplitude of the traveling wave (default: 0.001T).

Related Procedures

Setting parameters for the analytical simplified model

Setting parameters for the numerical continuum model